Specifications; Control Panel - Texecom Premier 48 Installation Manual

Security control panels
Hide thumbs Also See for Premier 48:
Table of Contents

Advertisement

Premier 48, 88, 168 & 640 Installation Manual

6. Specifications

Control Panel

Power supply
Mains Supply Voltage:
Maximum Total Current Rating
16.5V
, 40VA transformer:
AC
Ripple
Power Supply
Battery Charging Current
Maximum Available Current
PD6662 Rated Output
Standby Battery Capacity
Recharge Time
Low Battery Fault
Deep Discharge Protection
Electrical
Current Consumption 48/88/168
Quiescent
Alarm (Nothing Connected)
Current Consumption 640
Quiescent
Alarm (Nothing Connected)
Fuses
Mains (2.0A
)
DC
Battery
Auxiliary
Bell
Network 1 (48/88/168)
Network 2 (168)
Networks 1 to 8 (640)
Data Network
Remote Keypads
Premier 48
Premier 88
Premier 168
Premier 640
Expanders
Premier 48
Premier 88
Premier 168
Premier 640
Output Modules
Premier 48
Premier 88
Premier 168
Premier 640
INS176
230V
(±10%)
AC
2.0A
DC
<5%
2A
750mA
1.25A
See Page 11
7Ah to 18Ah
<24Hrs
10.5V
9.5V
70mA
70mA
160mA
160mA
500mA, 250V, 20mm
1.6 Amp, 250V, 20mm
1 Amp, 250V, 20mm
1 Amp, 250V, 20mm
1 Amp, 250V, 20mm
1 Amp, 250V, 20mm
900mA, 250V PTC
4-wire standard 7/0.2
alarm cable up to 500m
Star, Daisy Chain or any
combination of the two
Up to 4
Up to 8
Up to 16
Up to 64
Up to 4
Up to 8
Up to 16
Up to 64
Up to 2
Up to 4
Up to 8
Up to 32
Zones
Premier 48
Premier 88
Premier 168
Premier 640
EOL Resistor Values
EOL Resistor
Contact Resistor
Fault Resistor
0 - 1k
1k1 to 4k
4k1 to 5k6
5k7 to 8k
8k1 to 20k (30k)
21k+ (30k+)
Digicom Outputs
Outputs 1 to 8
Panel Outputs
Outputs 1 & 2 (48/88/168/640)
Outputs 3 & 4 (88/168/640)
Output 5 (88/168/640)
Siren Outputs
Bell Trigger
Strobe Trigger
Speaker Output
Environmental
Operating Temperature
Storage Temperature
Maximum Humidity
EMC Environment
Physical
Housing
Dimensions (W x H x D)
Battery Compartment
Packed Weight
Specifications
8 expandable to 48
8 expandable to 88
8 expandable to 168
0 expandable to 640
2k2 (3k3)
4k7 (3k3)
2k2
Zone Short
Zone Secure
Zone Fault
Zone Active
Zone Mask
Zone Tamper
100mA switched to 0V
500mA switched to 0V
500mA switched to 12V
3 Amp Relay
1A switched to 0V
1A switched to 0V
Minimum load 8Ω
-10°C (+14°F) to
+55°C (+131°F)
-20°C (-4°F) to
+60°C (+140°F)
95% non-condensing
Residential
Commercial
Light Industrial
Industrial
Metal
305mm x 405mm x
100mm x 2mm Steel
Up to two 12V 7.0Ah
batteries or one 12V 18Ah
battery
5.5 Kg
99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premier 168Premier 88Premier 640

Table of Contents