Programming the Control Panel
26 - Keypad PA Delay
When keypad 'option 6' is programmed as 'PA Delayed' (see
page 57 for details), and a keypad PA alarm (1 & 3) is
activated, this timer starts. If a User code is entered before
this timer expires, no PA alarm will occur. However, if a User
code is not entered before this timer expires, a PA alarm will
occur.
27 - Confirmation Dly
When an Intruder alarm occurs, this timer starts. If a second
(different) zone is activated within this time window, the
'Confirmed'
output
will
expires, the 'Confirmed' output will no longer activate.
28 - Warning Delay
When a Custom zone with the 'Warning Req' attribute (see
page 38 for details) activates, this timer is started. If the zone
is still active when this timer expires a warning tone or alarm
will occur and the Warning Output (see page 64 for details)
will activate.
29 - Keypad Lock Time
When code tampers are programmed to lockout the keypad
(see page 49 for details), the keypad will lock out for the
duration of this timer.
30 - Eng. log off Dly
This timer starts when an Engineers code is entered. When the
timer expires the engineer is automatically logged out of
engineer's mode. This timer is suspended if there are tamper
faults on the system allowing the engineer to remain in
engineer's mode indefinitely whilst on site.
31 - Fire Bell Delay
This timer starts when a fire alarm is generated in a particular
area. When the timer expires sounders are activated in ALL
areas.
32 - Forced Entry Dly
When a zone with the 'Guard' attribute (see page 37 for
details) activates, this timer is started. For the duration of this
timer, any 'Entry/Exit 1 or 2' zone with the 'Entry/Exit 2'
attribute (see page 37 for details) will become a 'Guard' zone.
When this timer expires, the 'Entry/Exit 1 or 2' zone will revert
back to its normal mode of operation.
33 - Supervision Time
This timer controls the frequency at which the RadioPLUS
detectors are required to report in to the control panel.
34 - Poll IP Every
This timer controls the frequency that the ComIP Polls the
ARC.
48
activate.
When
this
Premier 48, 88, 168 & 640 Installation Manual

System Config.

timer
These options control how various system functions work.
00 - No Bell Arm Fail
If an area fails to arm, an Internal alarm will occur and the
'Strobe' output will activate.
Bell on Arm Fail
If an area fails to arm, an Internal alarm will occur and the
'Bell' output will activate for 10 seconds.
The 'Strobe' output will also activate for 5 seconds to
indicate that the system has armed/disarmed.
01 - Bell is an SAB
The 'Bell' output on the control panel applies 0V when active.
Bell is an SCB
The 'Bell' output on the control panel removes 0V when active.
02 - Clock is 24Hr
The system time is displayed in the 24-Hour format.
Clock is 12Hr (Default)
The system time is displayed in the 12-Hour format.
03 - Auto BST/GMT
The system clock will adjust itself at the beginning and the
end of the summer (the clock will automatically gain 1Hr on
the last Sunday in March and lose 1Hr on the last Sunday in
October.
Manual BST/GMT
The system clock will not adjust itself at the beginning and
the end of the summer (the clock will have to be adjusted
manually).
04 - View Armed Areas
When the system is part armed, the areas that are armed are
displayed and alarm information is displayed before a valid
User code is entered.
Hide Armed Areas
When the system is part armed, the areas that are armed are
not displayed and alarm information is only displayed after a
valid User code has been entered.
Yes
1
Yes
Yes
Enter a configuration
??
number or use the
SCROLL key to search
e.g. 09 = NVM Unlocked
Press NO to change
No
the config. option
Yes