Programming the Control Panel
20 - Predictive Text
When in text editing mode, the control panel will
automatically select predictive text.
Manual Text Edit
When in text editing mode, the control panel will
automatically select normal text.
21 - Short = Tamper
The control panel will see a zone that is in the short circuit
condition as a 'Tamper'.
Short = Active
The control panel will see a zone that is in the short circuit
condition as 'Active'.
22 - R/R=Reset Only
When 0V is applied to the control panel R/R input, any areas
programmed for anti-code reset (see page 43 for details) that
are in alarm, will be reset.
R/R=Silence/RST
When 0V is applied to the control panel R/R input any areas
programmed for anti-code reset (see page 43 for details) that
are in alarm, will be silenced. When 0V is applied to the R/R
input a second time, the areas will be reset (this would
normally be used when Audio Verification is required).
23 - User Code Pulse
The control panel will see a zone that is in the short circuit
condition as 'Active'.
User Code Latch
The control panel will see a zone that is in the short circuit
condition as a 'Tamper'.
24 - Timed Test Call
A test call to the Alarm Receiving Centre will occur every time
the 'Test Call Every' timer expires.
Test Call = CT7
A test call to the Alarm Receiving Centre will occur every time
'Control Timer 7' activates.
25 - Batt Test Timed
A battery test will occur every time the 'Batt Test Period' timer
expires.
Batt Test = Disarm
A battery test will occur every time the system is disarmed or
after the 'Batt Test Period' timer has expired (whichever
occurs first).
26 - Bell = 1st Alarm
The 'Bell' and 'Strobe' outputs will activate after an Intruder
alarm (1st Alarm) occurs.
Bell = 2nd Alarm
The 'Bell' and 'Strobe' outputs will activate after a Confirmed
alarm (2nd Alarm) occurs.
27 - SNDR = 1st Alarm
The internal sounders will sound after an Intruder alarm (1st
Alarm) occurs.
SNDR = 2nd Alarm
The internal sounders will sound after a Confirmed alarm
(2nd Alarm) occurs.
28 - Conf. = Instant
Following the arming of the system/area, if two zones activate
(causing a Confirmed alarm), the signal will be reported to the
Alarm Receiving Centre immediately.
Conf. = Delayed
Following the arming of the system/area, if two zones activate
(causing a Confirmed alarm), the signal will only be reported
to the Alarm Receiving Centre after the 'Abort' time has
expired.
50
Premier 48, 88, 168 & 640 Installation Manual
29 - Abort=Eng.Reset
An Intruder alarm that is aborted can only be reset by an
Engineer/Anti-code.
Abort=User Reset
An Intruder alarm that is aborted can be reset by any User.
30 – Auto AV Output
When using the AV Module, if a microphone is remotely
selected, the corresponding output automatically activates.
Manual AV Output
When using the AV Module, if a microphone is remotely
selected, the corresponding output must be activated
manually.
31 - Clock = 50Hz
The internal clock on the control panel runs from the 50Hz
main frequency.
Clock = Crystal
The internal clock on the control panel runs from the built-in
crystal.
32 - 80 Column Print
Select this option when connecting an 80 Column printer to
the control panel.
40 Column Print
Select this option when connecting an 40 Column printer to
the control panel.
33 - Disable Text
Areas that are armed are displayed as letters on the bottom
line of the display i.e. 'Armed: AB.D...'
Enable Text
Areas that are armed are displayed using their assigned text
on the bottom line of the display i.e. 'Armed: Garage', 'Office'
etc. (a different area is displayed every second).
34 - EN50131 Disabled
The Control Panels EN50131 options are disabled.
EN50131 Enabled
Keypad display 'blanking' is enabled i.e. the keypad will only
display the time, date and the banner message. If information
is available to be viewed i.e. AC Mains Fail, Line Fault,
System Faults etc. the keypad will bleep every 30 seconds
and display 'System Alerts', this information can only be
viewed after a valid user code has been entered. The keypad
display will then 'blank' again 30 seconds after.
The bell output will not activate, if an alarm occurs during the
entry mode.
Duress Codes can only be programmed by an engineer
35 - 2nd Zone = Confirm
After the entry timer has expired, activation of 2 more zones is
required to generate a Confirmed alarm
1st Zone = Confirm
After the entry timer has expired, activation of 1 more zone is
required to generate a Confirmed alarm
36 - Keypads Global
Keypads show information for all areas.
Keypads Local
Keypads only show information that is relative to the area that
the keypad is assigned to.
37 - Panel Grade 3
All options relating to PD6662: 2004/EN 50131-1 Grade 3 are
enabled automatically. Also, the Premier Anti-code reset
becomes a 6-digit number and all user codes can only be
programmed as 5 or 6 digits, see page 29 for details.