Premier 48, 88, 168 & 640 Installation Manual
34 - Armed = Coms
When Areas are assigned to 'Armed = Coms' the system will
respond as follows:
Communications and outputs (Alarm, Confirmed etc.) for
ALL areas will only operate when all of the assigned areas
are armed.
When No Areas are assigned to 'Armed = Coms' the system
will respond as follows:
Communications and outputs (Alarm, Confirmed etc.) for
ALL areas will operate as normal.
35 - 2-Wire Smoke
Areas assigned to '2-Wire Smoke' will register a Fire Alarm
when any 2-Wire Smoke detector activates.
Areas not assigned to '2-Wire Smoke' will not register a Fire
Alarm when a 2-Wire Smoke detector activates.
36 - Faults Eng Reset
Each area can be programmed for Engineer or User reset
following any Fault. Areas Assigned to 'Faults Eng Reset' will
respond as follows:
The assigned areas can only be reset using an Engineer
code
If 'Anti-code Reset' is enabled (option 11) the assigned
areas can also be reset using the Anti-code
Areas not assigned to 'Faults Eng Reset' can be reset with
any User code that is valid for those areas.
37 - No ATS Eng Reset
Each area can be programmed for Engineer or User reset
following a "No ATS Available" fault (ATS = Alarm
Transmission System). Areas Assigned to 'No ATS Eng
Reset' will respond as follows:
The assigned areas can only be reset using an Engineer
code
If 'Anti-code Reset' is enabled (option 11) the assigned
areas can also be reset using the Anti-code
Areas not assigned to 'No ATS Eng Rst' can be reset with any
User code that is valid for those areas.
38 - AC Fail Eng Reset
Each area can be programmed for Engineer or User reset
following an AC Mains Fail. Areas assigned to 'AC Fail Eng
Reset' will respond as follows:
The assigned areas can only be reset using an Engineer
code
If 'Anti-code Reset' is enabled (option 11) the assigned
areas can also be reset using the Anti-code
Areas not assigned to 'AC Fail Eng Reset' can be reset with
any User code that is valid for those areas.
39 - Mask When Armed
Areas assigned to 'Mask When Armed' will register a Masking
fault when the selected areas are armed and a Masking Fault
occurs.
Areas not assigned 'Mask When Armed' will never register a
Masking fault when the selected areas are armed and a
Masking Fault occurs
INS176

Time Arm Area

Yes
6
mno
Yes
5
jkl
Yes
Yes
3
def
Yes
Yes
The alarm system as a whole or any number of individual
areas can be automatically armed or disarmed using the built
in control timers.
The Premier 48 has 4 independent control timers and the
Premier 88, 168 and 640 all have 8 independent control
timers that may be configured to switch on and off at different
points of the day and operate on different days of the week
(see page 52 for programming details).
Programming the Control Panel
Use the SCROLL key
to select an area
Use keys 1 - 8 to select
a timer e.g. 5 = Timer 5
Press YES to select
the disarmed by timer
Use keys 1 - 8 to select
a timer e.g. 3 = Timer 3
45