Output Group - Zone; Output Group - User Code Entered; Output Group - Control Timer; Output Group - Pc Control - Texecom Premier 48 Installation Manual

Security control panels
Hide thumbs Also See for Premier 48:
Table of Contents

Advertisement

Premier 48, 88, 168 & 640 Installation Manual
55 - Arm Fail Warning
This output type activates when the selected area fails to arm
after a period of time (controlled by the area exit time) when
using 'Entry/Exit' or 'Exit Term.' arming and deactivates when
the area arms.
56 - Forced Entry
This output type activates for the duration of the 'Forced
Entry' timer (see page 48 for details) when any 'Guard' or
'Custom' zone with the 'Guard' attribute is activated (see
page 37 for details),.
57 - Zones Locked Out
This output type activates when any zone is locked out
following an Intruder Alarm activation and deactivates when
all zones are clear and reinstated.
58 - All Areas Armed
This output type activates when all of the selected areas are
armed and deactivates when any one of those areas is
disarmed.
59 - Time Arm Disabled
This output type activates when the timed arming procedure
is disabled (see page 38 for details) and deactivates when
timed arming is reinstated.
60 - Armed/Alarm
This output type activates when the selected area is armed
and deactivates when the selected area is disarmed
This output type also pulses when an Intruder alarm occurs in the
selected area, and deactivates when the selected area is
disarmed.
61 - Intruder Alarm
This output type activates when an Intruder alarm occurs, and
deactivates when the Intruder alarm is cancelled.
Tamper alarms will not activate this output
62 - Speaker Mimic
This output type activates whenever the internal speaker
output is on, and deactivates when the speaker output is off.
63 - Full Armed/Exit
This output type activates when the selected area is in the full arm
exit mode and then arms and deactivates when the area is
disarmed.
64 - Detector Fault
This output type activates when a detector fault occurs and
deactivates when the fault is reset.
65 - Detector Masked
This output type activates when a detector mask occurs and
deactivates when the mask is reset.
66 - Fault Present
This output type activates when a general fault occurs i.e.
Line Fault, AC Mains Fail, Detector Fault etc. and deactivates
when the fault is cleared.
67 - LED Control
This output type is always activate and deactivates when a
User or Engineers code is entered to gain access to a menu.
The
output
activates
user/engineer exits the menu. This output type is for use with
detectors that require 0V applied to disable their LED's.
68 - Full Arm Entry
This output type activates when the entry mode is started and
deactivates when the entry mode finishes whenever the
system in Full Armed.
INS176
again
30
seconds
after

Output Group - Zone

Any zone can be assigned to this output type. Select a zone
number from 1 to 48 (Premier 48), 1 to 88 (Premier 88) or 1 to
168 (Premier 168).then select an output type from the following
options:
Mimic
This output type activates when the selected zone is activated
and deactivates when the zone is secure. This output will
work if the zone is armed or disarmed.
MimicArm
This output type activates when the selected zone is activated
and deactivates when the zone is secured. This output will
only work if the zone is armed.
Alarm
This output type activates when the selected zone causes an
alarm and deactivates when the alarm is reset. This output
will only work if the zone is armed.
Tamper
This output type activates when the selected zone causes a
Tamper alarm and deactivates when the tamper is reset. This
output will work if the zone is armed or disarmed.
MimicLat
This output type activates when the selected zone is activated
and deactivates when the next time the zone is activated. This
output will work if the zone is armed or disarmed.
Omitted
This output type activates when the selected zone is omitted
and deactivates when the zone is reinstated.

Output Group - User Code Entered

Any user can be assigned to this output type. Select a user
number from 1 to 25 (Premier 48), 1 to 50 (Premier 88) or 1 to 99
(Premier 168).
This output type activates for 5 seconds when the selected
User code is entered.

Output Group - Control Timer

Select a Control Timer from 1 to 4 (Premier 48) or 1 to 8
(Premier 88/168).
These output types activate when the respective control timer
turns on and deactivate when the timer turns off.

Output Group - PC Control

Select a PC Control from 1 to 4 (Premier 48), 1 to 8 (Premier
88/168/640).
These output types can be activated and deactivated using a
PC running the Wintex UDL software.

Output Group - Door Control

the
Select a Door Control from 1,1 to 1,4 (Premier 48), 1,1 to 1,8
(Premier 88), 1,1 to 2,8 (Premier 168) or 1,1 to 8,8 (Premier 640).
These output types activate for the duration of the 'Door
Strike' timer when a valid User code (assigned to the same
door) is entered and deactivates when the timer expires.
These output types are used in conjunction with the 'Door
Control' User option (see page 88 for details).