Premier 48, 88, 168 & 640 Installation Manual
5.9 Engineer Utilities
View Event Log
Yes
Yes
1
Chime
Area
Part
Menu
INS176
Use keys 1 or 2 to select
the System or Alarm log
i.e. 1= System Log
Use the SCROLL key to move up and
down through the log. DOWN moves to
the previous event (backwards in time)
and UP moves forwards again. Or
use one of the
available h
otkeys
Press CHIME. to find any
preceding events relating to
the displayed event i.e.
User codes being entered
Press AREA. to toggle the
display between the Area
information and the time/date
Press PART to display any
programmed zone text etc.
The control panel has two Event Logs, which are time and
date stamped. The first log which is a system log, records all
events that occur on the system, i.e. Users entering their
codes to arm or disarm areas, alarm events, failures to arm
etc. and the second log which is an alarm log, only records
alarm events that occur on the system.
Event Log Hotkeys
When viewing the system log there are 8 hotkeys available.
These hotkeys allow certain events to be found easier without
the need for searching.
The following hotkeys are available:
= Priority Alarms (PA, Fire etc.)
= Normal Alarms (Guard, 24hr, Entry/Exit etc.)
= Opens and Closings (Arm, Disarm etc.)
= Omits and Reinstates (Zone Omits etc.)
= Maintenance (System Tests, Engineer Program etc.)
= Tampers (Zone, Bell, Aux etc.)
= Test Calls (Communicator Active, successful etc.)
= Entry/Exit (Entry and Exit Procedures)
= User Codes (User codes being used)
Programming the Control Panel
89