Event Log Descriptions - Texecom Premier 48 Installation Manual

Security control panels
Hide thumbs Also See for Premier 48:
Table of Contents

Advertisement

Programming the Control Panel

Event Log Descriptions

Log Event
### ARM FAILED
### Flt Alarm
### Mask Alarm
### Test Failed
### Tested OK
#,# RESET AREAS -
AC Off Alarm
ALARM ABORT
ALARM Active
Anti-Code Reset
AREA Armed
AREA Disarmed
ARMED WITH L/F
ARMING FAILED
ARMING SUITE #
ATS FAILED
ATS FLT Alarm
AUTO TEST CALL
AUX #,# Tamper
AV CLEARED by ##
BELL #,# Tamper
BELL Active
BELL FUSE Alarm
BOX LID Tamper
CODE #,# Tamper
Com??? Line Fault
COM PORT Alarm
CONFIRMED ALARM
CORRUPT EVENT
CROSS ### Alarm
DATA CHANGED
DATE CHANGED
DEFAULTS LOADED
DEFERRED
DOOR #,#
DOWNLOAD START
DOWNLOAD END
DURESS
Engineer Reset
ENTRY Area ##
EXIT Area ##
EXP #,# Reset
EXP #,# Line Fault
EXP #,# LOST
EXP #,# Tamper
F_PA ##
Fault Override
FIRE ### Active
FIRE ### Tamper
FIRST KNOCK ###
FUSE #,# Alarm
GSM MODULE LOST
iD Loop# Tamper
Key switch Reset
KSW ### Disarmed
LOG ALERT
LOG CLEARED
LOW BAT Alarm
LOW V #,# Alarm
90
An exit fault from Zone ### has caused the system to fail to arm
Zone ### has detected a Fault condition
Zone ### has detected a Mask condition
Zone ### has activated whilst it has been on soak test
Zone ### has activated during the walk test
Area have been reset using keypad #,# following an Intruder alarm
The control panel has detected an AC Mains failure
An Open After Alarm-Abort has occurred for area ?
An Intruder alarm signal has been activated for area ?
A reset has been performed using the Anti-code reset procedure
Area ? has been armed
Area ? has been disarmed
The system has been armed with a Line Fault condition present
A Exit Error-Arm Fail has occurred on area ?
Area Arm Suite # was used to arm the system
The Com300 or Com2400 has failed to report to the Alarm Receiving Centre
There is a problem with the telephone line
An Automatic test call has been initiated
An Auxiliary Tamper input from device #,# has been activated
The Audio Verification unit has been cleared down by user ##
A Bell Tamper input from device #,# has been activated
The Bell output has been activated for area ?
The control panel Bell Fuse has failed
The control panel lid has been removed causing a Tamper alarm
Too many invalid key presses have caused a tamper alarm from keypad #,#
The Com300, 2400 or ISDN has detected a line fault
A com port has generated an alarm
Two or more detectors have activated, resulting in a confirmed alarm condition
No event has been stored in memory
A Verified Cross Zone Alarm has occurred from zone ###
Programming data has been changed
The control panel Time has been changed
The factory default values have been loaded into memory
The arming mode was deferred for area ?
Door #,# has been opened by a user with Door Control
An Upload/Download has been initiated
The Upload/Download has finished
User ## has entered a Duress Code at a keypad
A reset has been performed using an Engineers code
The Entry mode has been started for area ?
The Exit mode has been started for area ?
A reset has been performed using the input on expander #,# (programmed as reset)
The Input on expander #,# (programmed as line fault) has been activated
Expander ## has been lost from the network
The cover of expander #,# has been removed
A Panic Alarm from a Radio FOB has been generated
The system has been armed with a Fault condition present by a user
Zone ### (programmed as Fire Alarm) has caused an alarm
Zone ### (programmed as Fire Alarm) has caused an Tamper alarm
Zone ### (which is programmed as double knock) has activated for the first time
The Auxiliary 12V Fuse in device #,# has failed
The GSM Module has lost communications with the control panel
There is a short circuit on iD loop # on the iD expander
A reset has been performed using a key switch
A Keyswitch zone type has been activated (zone number ###)
80% of the Event Log has filled (since the last Upload/Download)
The event log has been erased
The control panel has registered a low battery condition
Expander #,# has detected that's its supply voltage is low
Premier 48, 88, 168 & 640 Installation Manual
Description
INS176

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premier 168Premier 88Premier 640