Premier 48, 88, 168 & 640 Installation Manual

Panel Outputs 1 - 5

The control panel has five programmable outputs, which can
be used to drive auxiliary devices such as LED's, sounders or
relays etc. (see page 60 for details). The table below shows
the electrical characteristics for each output:
No
Max Current
1
1A
2
1A
3 *
1A
4 *
1A
5 *
3A
* Premier 88, 168 and 640 only
Wiring Outputs
The diagram below shows some typical wiring examples:
For details on testing outputs, see page 92
INS176
Type
Switched -ve
Switched -ve
Switched
ve
+
Switched
ve
+
Relay

Digicom Outputs 1 - 8

The control panel has eight programmable outputs, which
can be used for connecting to a stand-alone communicator
(see page 61 for details). The table below shows the electrical
characteristics for each output:
Terminal
Max Current
1
100mA
2
100mA
3
100mA
4
100mA
5
100mA
6
100mA
7
100mA
8
100mA
L/M
N/A
R/R
N/A
DC+
N/A
DC-
N/A
* Control Panel Line Fault Input (L/M)
In accordance with BSIA form 175, the line fault input on the
control can detect a single or a dual line fault for use with the
ATS Remote Test output type
Wiring a Stand Alone Communicator
The diagram below shows a typical wiring example:
Stand Alone
Communicator
Line Fault
C
12V
Power
0V
1
3
Channel Inputs
4
Programmed
5
as Positive
Removed
6
7
8
For details on testing the digicom outputs, see page 92
Installation
Operation
Switched 0V
Switched 0V
Switched 0V
Switched 0V
Switched 0V
Switched 0V
Switched 0V
Switched 0V
12V applied = Line Fault *
0V applied to reset
+12V Power (unfused)
0V Power
Control
Panel
L / M
R / R
DC +
DC -
1
3
4
Digicom
Outputs
5
6
7
8
21