Factory Defaults - Texecom Premier 48 Installation Manual

Security control panels
Hide thumbs Also See for Premier 48:
Table of Contents

Advertisement

Premier 48, 88, 168 & 640 Installation Manual

4. Factory Defaults

Menu
User Codes
Setup Users
User 00 (Engineer)
User 01 (Master)
All Other Users
1. Zone Setup
Zones Types
1
2
3 - 8
All Other Zones
Zone Areas
All Zones
Zone Text
All Zones
Zone Chime
All Zones
Zone Mask
All Zones
2. Area Programming
Timers
Exit Delay
(All Areas)
Entry Delay 1
Entry Delay 2
2
nd
Entry Dly
Bell Delay
Bell Duration
Coms Delay
Part Bell Dly
Arming Modes
All Areas
Area Arm Suites
All Suites
Area Suite Text
All Suites
Suite Arm Modes
All Suites
Area Options
1: Auto Part Arm
2: Part Arm Instant
3: Part Arm Silent
4: Remote Arm
5: Remote Disarm
6: Panel Tamper
7: Bell Tamper
8: Auxiliary Tamper
9: Panel Speaker
10: Bell & Strobe op
11: Alarm Eng Reset
12: Confirmation Reset
13: Tamper Eng Reset
14: Anti-code Reset
15: ATS Path Faults
16: Arm With No ATS
17: AC Mains Fail
18: Arm With AC Fail
19: Full Arm Coms
20: Part Arm Coms
21: Unarm Fire Coms
22: Unarm Tamp Coms
23: Auto Arm Areas
24: Area A Foyer
25: Log Part Omits
26: Multi Knock Area
27: UDL Keypad
28: Auto Chime (C2A)
29: Confirm In Entry
30: Conf. After Entry
31: Part Arm Enabled
32: Bell Squawk
33: Fob After Entry
34: Armed = Coms
35: 2 Wire Smoke
36: Faults Eng Reset
37: No ATS Eng Reset
38: AC Fail Eng Rst
39: Mask When Armed
Area Text
All Areas
INS176
Option
Default
1234
5678
Not Defined
Entry/Exit 1
Guard Access
Guard
Not Used
Area A
Not Defined
Silent
On
030 Seconds
045 Seconds
045 Seconds
000 Seconds
000 Minutes
015 Minutes
000 Seconds
000 Seconds
Entry/Exit
No Areas
Not Defined
Timed
No Areas
No Areas
No Areas
All Areas
All Areas
Area A
Area A
Area A
All Areas
All Areas
No Areas
All Areas
All Areas **
All Areas
Area A
No Areas **
Area A
Area A
All Areas
No Areas
No Areas
All Areas **
No Areas
No Areas
No Areas
No Areas
All Areas
No Areas
No Areas
All Areas
ALL Areas
No Areas
All Areas
No Areas
No Areas
All Areas **
All Areas **
All Areas **
All Areas
Not Defined
Menu
3. Global Options
System Timers
1: Exit Settle Time
2: Global Bell Dly.
3: Global Bell Dur.
4: Double Knock Dly
5: Beam Pair Time
6: Activity Delay
7: Abort Delay
8: Courtesy Time
9: Defer Arming By
10: Auto Arm Delay
11: Menu Time Out
12: Pulse Period 1
13: Pulse Period 2
14: Pulse Period 3
15: ATS Fault Delay
16: AC Off Delay
17: Batt Test Period
18: Batt Test Time
19: Soak Test Time
20: Service Interval
21: Test Call Every
22: Min Random Time
23: Max Random Time
24: Door Strike Time
25: Zone Response
26: Keypad PA Delay
27: Confirmation Dly
28: Warning Delay
29: Keypad Lock time
30: Eng. Log Off Dly
31: Fire Bell Delay
32: Forced Entry Dly
33: Supervision Time
34: Poll IP Every
System Config.
00: Bell on Arm Fail
01: Bell is an SCB
02: Clock is 12Hr
03: Manual BST/GMT
04: Hide Armed Areas
05: Area Bell Time
06: 24Hr Omit Local
07: Leave Omits
08: Enforce Com Delay
09: NVM is Locked
10: Engineer Only
11: Chime Visible
12: Omit Tampers NO
13: Offline Printing
14: View Act. Fault
15: Hide Exit Errors
16: No Code Tamp
17: Code Tamp Alarms
18: Areas 1-8 & I-P
19: Man. Area Select
20: Normal Text
21: Zone Short = Active
22: R/R=Silence/RST
23: User Code Latch
24: Test Call = CT4
25: Batt Test = Disarm
26: Bell = 2nd Alarm
27: SNDR = 2nd Alarm
28: Conf. = Delayed
29: Abort = User Reset
30: Manual AV Output
Factory Defaults
Option
Default
008 Seconds
000 Minutes
015 Minutes
007 Seconds
060 Seconds
024 Hours
180 Seconds
060 Seconds
030 Minutes
030 Minutes
180 Seconds
010 Seconds
020 Seconds
030 Minutes
000 Minutes
005 Minutes
024 Hours
010 Seconds
014 Days
000 Weeks
024 Hours **
000 Seconds
060 Seconds
005 Seconds
008 x 8mSec.
060 Seconds
060 Minutes
000 Minutes
090 Seconds
060 Minutes
000 Minutes
005 Seconds
030 Minutes
000 Minutes
No Bell
SAB
24Hr
Auto
View
Global
Global
Remove
Override
Unlocked
User + Engineer
Audible
YES **
Online
Hide
Hide
Enable
Locks **
A-H & I-P
Auto
Predictive
Tamper
Reset Only
Pulse
Timed
Timed
1st Alarm
1st Alarm
Instant
Eng.
Auto
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premier 168Premier 88Premier 640

Table of Contents