Global Options - Texecom Premier 48 Installation Manual

Security control panels
Hide thumbs Also See for Premier 48:
Table of Contents

Advertisement

Premier 48, 88, 168 & 640 Installation Manual
System Timers
System Config.
System Options
Monitor Hardware
Control Timers
System Text
Part Arm Text
Holiday Dates
Speaker Tones
PC Output Text
Custom O/P Text
INS176
Use
to select a timer,
01:
Exit Settle Time
02:
Global Bell Dly.
03:
Global Bell Dur.
04:
Double Knock Dly
05:
Beam Pair Time
06:
Activity Delay
07:
Abort Delay
08:
Courtesy Time
09:
Defer Arming By
10:
Auto Arm Delay
11:
Menu Time Out
12:
Pulse Period 1
Use
to select an option,
00:
(No Bell/Bell on) Arm Fail
01:
Bell is an (SAB/SCB)
02:
Clock is (12Hr/24Hr)
03:
(Manual/Auto)
BST/GMT
04:
(Hide/View) Armed Areas
05:
(Area/Global) Bell Time
06:
24Hr Omit (Global/Local)
07:
(Leave/Remove) Omits
08:
Away (Override/Enforce) Delay
09:
NVM is (Unlocked/Locked)
10:
Engineer (Only/+ User)
11:
Chime (Audible/Visible)
12:
Omit Tampers (NO/YES)
13:
(Offline/Online) Printing
14:
Activity Fault (View/Hide)
15:
(Hide/View) Exit Errors
16:
(No/Enable) Code Tampers
17:
Code Tamp (Alarms/Locks)
18:
Areas (1-8/A-H) & I-P
19:
(Auto/Manual) Area Select
Use
to select an Option,
1:
Advisory Volume
2:
Chime Volume
3:
Number Of Re-Arms
Press
to edit,
to select an option,
P = ATS Path Fault
A = AC Power
F = Aux Fuse Blown
Use
to select an area,
Use
-
to select the 1
Use
-
to enter the 1
Use
-
to select the 1
Use
to select a message,
appropriate number of times),
Use
to select a Part Arm,
(press the required key the appropriate number of times),
Use
to select a holiday date,
(
Use
to select a tone type,
Use
to select an Output,
key the appropriate number of times),
Use
to select an Output,
key the appropriate number of times),

Global Options

-
to enter a value,
13:
Pulse Period 2
14:
Pulse Period 3
15:
ATS Fault Delay
16:
AC Off Delay
17:
Batt Test Period
18:
Batt Test Time
19:
Soak Test Time
20:
Service Interval
21:
Test Call Every
22:
Min Random Time
23:
Max Random Time
24:
Door Strike Time
to change the option,
20:
21:
22:
23:
24:
25:
26:
27:
28:
29:
30:
31:
32:
33:
34:
34:
35:
36:
37:
38:
-
to enter a value,
4:
Anti-code Resets
5:
Multiple Knocks
6:
Modem Levels
to change the option,
B = Bell Tamper
A = Aux Tamper
L = Panel Lid
-
to enter the 1
st
st
On time days of operation,
st
Off time,
to accept
st
Off time days of operation,
-
to select characters (press the required key the
to accept
to edit the Part Arm text,
-
to enter the required date
),
to accept
to turn the tone on/off,
to edit,
-
to accept
to edit,
-
to accept
Quick Reference Guide
to accept
25:
Zone Response
26:
Keypad PA Delay
27:
Confirmation Dly
28:
Warning Delay
29:
Keypad Lock Time
30:
Eng. Log Off Dly
31:
Fire Bell Delay
32:
Forced Entry Dly
33:
Supervision Time
34:
Poll IP Every
to accept
(Predictive/Normal) Text
Zone Short=(Active/Tamper)
R/R=(Reset Only/Silence/RST)
User Codes (Pulse/Latch)
Test Call = (Timed/Timed)
Batt Test = (Timed/Disarm)
Bell = (1
st
Alarm/2
nd
Alarm)
st
nd
SNDR = (1
Alarm/2
Alarm)
Conf. = (Instant/Delayed)
Abort = (Eng. Reset/User Reset)
(Auto/Manual) AV Outputs
Clock = (50Hz/Crystal)
(40/80) Column Printer
(Enable/Disable) Text
EN50131 (Disabled/Enabled)
(2
nd
Zone /1
st
Zone) = Confirm
(Global/Local) Keypads
Panel Grade (2/3)
(Enable/Disable) RF FOB PA
Mask=(Fault/Alarm)
to accept
7:
Quick Count
8:
Modem Level
to accept
B = Battery Faults
On time,
to accept
to accept
to accept
-
to select characters
to accept
to accept
to select characters (press the required
to select characters (press the required
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premier 168Premier 88Premier 640