Power Supply Ratings; Connecting Ac Mains; Connecting Batteries - Texecom Premier 48 Installation Manual

Security control panels
Hide thumbs Also See for Premier 48:
Table of Contents

Advertisement

Premier 48, 88, 168 & 640 Installation Manual
F1 - F5: Protection Fuses (Premier 48, 88 and 168)
The following fuses are provided:
F1 (1Amp) Auxiliary 12V Power fuse
F2 (1.6 Amp) Battery fuse
F3 (1 Amp) Network 1 fuse
F4 (1 Amp) Bell/Strobe fuse
F5 (1 Amp) Network 2 fuse (Premier 168 only)
F1 - F5: Protection Fuses (Premier 640)
The following electronic fuses are provided:
F3 (1600 mA) Battery
F4 (250mA) Speaker
F5 (900mA) Network 1
F6 (900mA) Bell/Strobe
F7 (900mA) Network 2
F8 (900mA) Network 3
F9 (900mA) Network 4
F10 (900mA) Network 5
F11 (900mA) Network 6
F12 (900mA) Network 7
F13 (900mA) Network 8
F14 (900mA) Auxiliary 12V

Power Supply Ratings

If installing to PD6662, the system standby times in the event
of a mains power failure vary depending on the grade and
how AC fail is signalled:
System Standby Times
Grade 2
AC Fail signalled
as AC Fail
12 Hours
12 Hours
The "Rated Power" of the control panel will depend on the
size of the standby battery, standby time and the installation
grade:
7 Ah Standby Battery
Max Power
Grade 2 –
Available
Rating
from control
panel
2 A
580mA
17 Ah Standby Battery
Max Power
Grade 2 –
Available
Rating
from control
panel
2 A
1.25A
When calculating the current consumption of the system you
must include the current taken by the control panel and all
the devices that it powers. If the total current exceeds the
"Rated Output" for the grade you are installing to then an
additional power supply is required.
INS176
Grade 3
Grade 3
AC Fail signalled
as Fault
24 Hours
Grade 3 –
Grade 3 –
Rating
Rating
AC Fail
AC Fail
signalled as
signalled as
AC Fail
Fault
580mA
290mA
Grade 3 –
Grade 3 –
Rating
Rating
AC Fail
AC Fail
signalled as
signalled as
AC Fail
Fault
1.25A
750mA

Connecting AC Mains

The AC Mains supply is connected to a 3 way 'Euro Type'
fused terminal block, which is fitted with a 125mA or 500mA
fuse.
All other wiring MUST be carried out before AC mains
is connected to the control panel.
After connecting the AC Mains, fit the mains cover, this
can be found in the spares bag.
To transformer

Connecting Batteries

If installing to PD6662: 2004 then only One 12V 7Ah battery
or 12V 17Ah battery can be fitted inside the control panel to
provide continued operation in the event of an AC mains
failure, otherwise, two 12V 7Ah batteries can be connected.
All other wiring MUST be carried out before the battery
is connected to the control panel.
Connect the red battery lead to the positive terminal of the
battery and then connect the black battery lead to the
negative terminal.
The panel will only become 'live' when the AC Mains is
connected or the 'Battery Kick-start' button is pressed.
+
12V 17Ah Battery
-
OR
+
12V 7Ah Battery
-
OR
If not installing to PD6662: 2004
+
12V 7Ah Battery
-
+
12V 7Ah Battery
-
Installation
L
E
N
+
Battery
_
+
Battery
_
+
Battery
_
11