System Design & Installation Considerations
Before attempting to install the alarm system, read this section. Once you have an overall understanding of the installation
sequence, carefully work through each step.
This quick reference guide will allow you to install your alarm system and programme all of the required basic functions.
Further in-depth programming options for the system are available in the manuals provided on the enclosed CD or on our
website.
1: Design the Layout
Make a rough sketch of the premises to get an idea of where all alarm detection devices, keypads and other modules are to be
located.
2: Arming/Disarming
It is highly recommended that SmartKey are used to arm and disarm the system. This will allow for the control panel and any
associated keypads to be placed in a secure area in the property.
3: Control Panel Location
The control panel should be mounted in a dry area close to an unswitched AC power source.
You must complete all wiring before connecting the battery, or applying AC Mains to the panel

Wiring the Control Panel

BEFORE connecting the control panel ALWAYS disconnect the supply at the consumer unit.
IMPORTANT SAFETY INFORMATION. HAZARDOUS VOLTAGES INSIDE, NO USER SERVICEABLE PARTS, NO USER
ACCESS.
ONLY connect the mains supply to the mains terminal block, NEVER connect the mains supply directly to the PCB.
ALWAYS refer to National Wiring Regulations when conducting installation.
An appropriate and readily accessible disconnection device (e.g. an unswitched fused spur) MUST be provided as part of the
installation.
The disconnection device must NOT be fitted in a flexible cord.
Where identification of the neutral in the mains supply is NOT possible a two-pole disconnection device MUST be used.
The building mains supply MUST incorporate appropriate short-circuit backup protection (e.g. a fuse or circuit breaker) of
High Breaking Capacity (HBC, at least 1500A).
Use mains cable of adequate carrying capacity for the rated current (i.e. at least 0.75mm

Connecting AC Mains

The AC Mains supply is connected to a 3 way 'Euro Type' fused terminal block, which is fitted with a 3A - 3.15A slow/medium blow
fuse.
All other wiring MUST be carried out before AC mains is connected to the control panel.
After connecting the AC Mains, fit the mains cover, this can be found in the spares bag.
F US E 3.15A
To PS U
4: Install the Keypads
Where separate keypads are supplied, if using them to Arm/Disarm the system, these should be located on the entry route. Mount
and connect the keypads to the control panel.
5: Zone Wiring
If any of the hardwired zones are to be used, Install detection devices and connect to the control panel.
6: Other Wiring
Complete all other wiring including bells or sirens and telephone line connections.
4
WARNING: ELECTRICITY CAN KILL
If in ANY doubt consult a qualified electrician.