Note:
After resetting, the PWR LED remaining lit steady amber or red indicates the FTP transfer
was not successful or that the firmware is corrupt. Please contact Dataradio system engi-
neering for assistance.
5. Verify the integrity of the newly transferred files.
a) Connect to the unit's IP address using an Internet browser such as IE (5.0 or later) or Mozilla.
b) Enter the user name and password (in the usual manner) and allow the Welcome page to load.
c) In the left pane, click on Unit Status. The Unit Identification and Status pane should display the
newly upgraded firmware in its Banner (should correspond to the upgrade package version) and the
H/W Status should also show Ok.
d) In the left pane, click on Maintenance, then on Package Control. Wait a few moments for the re-
sults to display. Figure 76 shows a "Pass" result indication.
7.6.1.1

File Integrity Failure

If the message in the result screen points out that file(s) failed the integrity check, retry the FTP transfer
for the failed files(s) again.
If the problem persists, please have the Package Control result screen indications handy and contact Da-
taradio system engineering for assistance.