6.7.6.2

Unit Configuration Control

Important note: Record all original HiPR-900 factory settings for possible future use.
Item
Active Configuration Description
User Configuration Settings
Firmware Upgrade Settings
Factory Settings
001-5099-000
Figure 75 - Maintenance - Unit Configuration Control (Initial screen)
Active Configuration Description Field – available by selecting "Check-
point User Configuration" radio button in the "User Configuration Set-
tings "portion of this window below.
Checkpoint User Configuration (Save User Configuration) – saves a set
of the current user configuration settings in the HiPR-900.
Click on the "Checkpoint User Configuration" radio button to activate
the "Active Configuration Description" field. Enter a descriptive title of
up to 40 characters to help identify the configuration settings to be
saved. Click on "Proceed" to save the settings to the unit. The new con-
figuration set overwrites the factory (or previously user saved) configu-
ration settings.
Restore User Configuration Checkpoint (Load User Configuration) – the
radio button is available if "User Configuration Settings" have been
previously saved. To restore to user configuration, click the "Restore
User Configuration" radio button. Check the title of the settings about
to be restored in the "Active Configuration Description" field and click
on "Proceed" to restore the settings to the unit.
Merge settings bundled in upgrade package with current configuration-
merges upgraded settings with the current configuration.
Note: the "firmware update" process will end up replacing an existing
configuration file with the one that came bundled with the firmware
upgrade package.
Restore Factory Settings: restores all settings to default factory confi-
guration.
Upon performing the firmware upgrade, should you decide to restore to
factory settings instead of to "merge with bundled settings", simply
select the "Restore Factory Settings' radio button right after performing
the firmware upgrade and click on "Proceed".
Important note:
Activating " Restore Factory Settings" will reset the IP address of the
unit. Have your record of all the original HiPR-900 factory settings han-
dy before proceeding with restoring to factory settings.