6.7.2.5.1.1.2
Type 4 outputs contain the following fields:
♦ Source MAC Address (Bridge mode): Hex numbers format [00:01:02:03]
or
Source IP Address (Router mode): Dotted decimal format
[111.222.333.444]
♦ Type of report: Decimal number (4) that identifies the report as a "type 4".
♦ # of fields: Decimal number indicating number of comma-delimited fields to follow
♦ Thinning value: Number of data packets before a diagnostic message is delivered
♦ Signal RSSI: Decimal level in calibrated dBm
♦ Background RSSI: Decimal level in calibrated dBm
♦ Forward power: Decimal indications in milliwatts
♦ Reverse power: Decimal indications in milliwatts
6.7.2.5.1.2
Output Samples
From command window, type telnet nnn.nnn.nnn.nnn 6272 and the unit's diagnostic output
will display on screen (where nnn.nnn.nnn.nnn is your unit's address in dot decimal format) (Thin-
ning value must not be zero).
Note:
No overhead is generated in the HiPR-900 unit if no online diagnostic connection is actually
made.
Sample output for bridge mode (no IP address available)
[00:00:03:89], 3, 5, 5, 0, 135, 33, 0
[00:00:03:09], 4, 5, 5, -75, -115, 990, 50
Sample output for router mode
[192.168.36.188], 3, 5, 10, 0, 127, 46, -42
[192.168.36.188], 4, 5, 10, -70, -107, 1000, 200
[192.168.36.204], 3, 5, 10, 0, 103, 42, -53
[192.168.36.204], 4, 5, 10, -70, -110, 1000, 200
Decoding the last two lines (see Table 8): unit is 192.168.36.204 IP address (in router mode), type of re-
port is 3 for the first line, 4 for the second line, there are 5 fields to follow for both reports, 1/10 sampled
packets are output, DC input is used, Volts are 10.3, Internal temperature is 42°C, PER of 10
carrier level of -70 dBm signal, an average background level of -110dBm, a forward power of 1000 mil-
liwatts (1.0 watt), and a reverse power of 200 milliwatts (0.2 watt).
Note:
While the diagnostic messages are generated in pairs (i.e. type 4 output follows type 3 output), it
may appear as though they arrive in random order (i.e. type 3 output followed by another type 3
output) .