No overhead is generated in the HiPR-900 unit if no online diagnostic connection is actually
made.
Sample output for bridge mode (no IP address available)
[00:00:03:09], 0, 9, 100, 1, 5, 38, -51, -70, -108, 1000, 200
[00:00:03:09], 0, 9, 100, 1, 5, 38, -51, -70, -111, 1000, 200
Sample output for router mode
[192.168.36.188], 0, 9, 10, 0, 127, 46, -42, -70, -107, 1000, 200
[192.168.36.204], 0, 9, 10, 0, 103, 42, -53, -70, -110, 1000, 200
Decoding the last line (see Table 10): unit is 192.168.36.204 IP address (in router mode), type of report 0,
there are 9 fields to follow, 1/10 sampled packets are output, DC input is used, Volts are 10.3, Internal
temperature is 42°C, PER of 10
-110dBm, a forward power of 1000 milliwatts (1.0 watt), and a reverse power of 200 milliwatts (0.2
watt). old
Field
#
1
Source IP address
2
Report Type
3
Number of Fields to Follow
Number of data packets before a diagnostic
4
message is delivered
5
Flags
6
Voltage Level
7
Internal Temperature
8
PER
9
Signal RSSI
10
Background RSSI
11
Forward power
12
Reverse power
001-5099-000
-5.3
, with a carrier level of -70 dBm signal, an average background level of
Table 10 - Decoding Sample Output for Router Mode
Field Name
89
Sample Output
Sample Output
Unit's IP address is
[192.168.36.204]
192.168.36.204
0
0
9
9
1/10 packets re-
ceived will generate
10
a diagnostic mes-
sage
0
DC input
103
10.3 V
42
42°C
-5.3
-53
10
-70
-70 dBm
-110 dBm
-110
1000
1000 mW (1.0 Watt)
200
200 mW (0.2 Watt)
HiPR-900 User Manual
Decoded

Advertisement

Table of Contents
loading

Table of Contents