9.33 Panel PCB ASSY
(1) Disconnect the Connector (CN2) and Flat cable (CN3) from the Panel PCB ASSY.
Connector
(2) Release the ten Hooks to remove the Panel PCB ASSY from the Panel unit generic.
Note:
The Panel PCB ASSY consists of two PCBs, and they are connected with a Flat cable.
Be sure to remove the two PCBs at the same time because the Flat cable might get
broken if you remove the PCBs.
Panel PCB ASSY
Hook
Flat cable
CN2
Fig. 3-121
Hook
Fig. 3-122
3-95
CN3
Panel PCB ASSY
Hook
Hook
Panel unit generic
Lock
Flat cable
Hook
Hook
Confidential