9.12.3Panel PCB ASSY, LCD, LCD relay PCB ASSY, LCD relay flat cable
(For LCD: 3.7 inch models)
(1) Disconnect the key PCB flat cable from the panel PCB ASSY and release it from the
securing fixtures.
(2) Peel the film. Unlock the lock to disconnect the LCD relay flat cable from the panel PCB
ASSY.
(3) Remove the three taptite cup B M3x10 screws. Release each hook to remove the LCD
presser and LCD from the panel cover.
(4) Remove the four taptite cup B M3x10 screws, and remove the shield plate cover and
panel PCB ASSY from the panel cover.
Shield plate cover
Key PCB flat cable
Panel PCB ASSY
Harness routing: Refer to
Taptite cup B M3x10
Taptite cup B M3x10
LCD presser
Film
LCD Relay flat cable
Lock
LCD
Hooks
Fig. 3-54
"7. Panel unit (3.7 inch
3-60
Hook
model)".