If you press "Y" (yes), you will then be prompted "File Exists, Override?"
Press "N" to abort changes and leave all data unchanged.
Press "Y" (yes) to continue with the save operation.
°
Press
(escape) again to return to the Database Programming menu.
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a "SEND" function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Monitor – Extension/CO Line
The DX-80 system allows users to monitor conversations at other extensions for the purposes of service observance.
Monitoring of busy Extensions and CO Lines is possible only at extensions with a Monitor Class of Service that has
priority over the Monitor Class of Service of the extension to be monitored.
Since this feature is very similar to Intrusion, it is possible to "shift" between these two features when Monitor has
been invoked.
This feature may violate privacy laws if used in a manner that is inconsistent with requirements of these
laws. Manufacturer assumes no responsibility with regard to the use of this feature. It is provided for the
virtue of ethical use only. YOU are responsible for using this feature appropriately considering all applicable
Related Features
Intrusion
Related Programming
Extension – Monitor Class
Operation
1.
Place a call to a busy extension or press a busy CO Line button.
monit
2.
Press [
]. The audio connection at the busy CO Line is connected to your extension. Also at this time,
the Mute function at your telephone is automatically activated, making the monitor condition as un-intrusive
as possible. The display indicates the internal extension that is being monitored.
intru
3.
You may press [
Analog Ports (Single Line Telephones)
When you have called an extension that is busy, dial
Conditions
a)
The highest level of priority in Monitor Class is "0."
b)
"9" is the least priority level.
c)
Monitor will not be allowed if the called extension's Monitor COS matches the calling extension Monitor
COS.
P7290 IMM
DX-80 I
NSTALLATION AND
LEGAL NOTICE:
laws.)
CO LN BUSY 742
cbck
monit
MONITOR EXT XXX
intru
] or Mute to intrude on the conversation (your voice part of the call.)
1
3-185
M
M
AINTENANCE
ANUAL
.