Yamaha 2008 Fazer FZ1-N Service Manual page 522

2008 motorcycle
Hide thumbs Also See for 2008 Fazer FZ1-N:
Table of Contents

Advertisement

2. Check:
• Coolant temperature sensor resistance
Out of specification → Replace.
Coolant
resistance
0 °C (32 °F) : 5.21–6.37 kΩ
80 °C (176 °F) : 0.29–0.35 kΩ
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester (Ω × 1k) to the
coolant temperature sensor "1" as shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
• Positive tester probe
Coolant temperature sensor terminal
• Negative tester probe
Coolant temperature sensor terminal
b. Immerse the coolant temperature sensor in
a container filled with coolant "2".
NOTE:
Make sure the coolant temperature sensor ter-
minals do not get wet.
c. Place a thermometer "3" in the coolant.
temperature
sensor
ELECTRICAL COMPONENTS
d. Slowly heat the coolant, and then let it cool
to the specified temperature indicated in
the table.
e. Check the coolant temperature sensor for
continuity at the temperatures indicated in
the table.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
EAS28300
CHECKING THE THROTTLE POSITION
SENSOR
1. Remove:
• Throttle position sensor
(from the throttle body)
2. Check:
• Throttle position sensor
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester (Ω × 1k) to the
throttle position sensor as shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
• Tester positive lead →
Blue "1"
• Tester negative lead →
Black/Blue "2"
b. Check the throttle position sensor maxi-
mum resistance.
Out of specification → Replace the throttle
position sensor.
Maximum throttle position sen-
sor resistance
4–6 kΩ at 20 °C (68 °F)
c. Connect the pocket tester (Ω × 1k) to the
throttle position sensor as shown.
• Tester positive lead →
Yellow "3"
• Tester negative lead →
Black/Blue "2"
8-153

Hide quick links:

Advertisement

Table of Contents
loading