6 Tighten the captive screws in the middle and on each end of the power cord retainer (see
Figure 91: Securing the BlackDiamond 8810 AC Power Cord Retainer
7 To power the system on, connect the other end of each installed AC power cord to the power source.
NOTE
Leave the ESD-preventive wrist strap permanently connected to the switch so that it is always available when you
need to touch ESD-sensitive components.

Disconnecting a BlackDiamond 8810 AC Power Cord

To disconnect a BlackDiamond 8810 AC power cord:
1 Attach the ESD-preventive wrist strap to your bare wrist and connect the metal end to the ground
receptacle on the top left corner of the switch chassis.
2 Disconnect the AC power cord from the power source.
3 Loosen the captive screws in the middle and on each end of the BlackDiamond AC power cord
retainer, using a #2 Phillips screwdriver.
4 Remove the BlackDiamond AC power cord retainer from the front of the switch.
5 Remove the end of the AC power cord from the power outlet(s) on the front of the switch.
NOTE
Leave the ESD-preventive wrist strap permanently connected to the switch so that it is always available when you
need to touch ESD-sensitive components.