Dialogic® Vision™ CX Video Gateway Administration Manual
•
When an individual log file reaches this maximum size, it is rolled over and a
new file is created. The maximum rollover files is five. At any point, there may
be six files for each type of log file: one active log file and five rollover log
files.
When video transcoder services are stopped and started, the logs directory is
•
rolled over. For example, the first time after installation, all logs are created in
the logs directory. If the video transcoder services are stopped and restarted,
logs.1 directory is created which stores past log files. Current logging occurs
in the logs directory. The logs directory rollover value is 2. At any point, there
may be three logs directories: logs, logs.1, and logs.2.
For example, in a system that uses 60 video transcoder channels, the maximum
number of log files that reside in the logs directory may be up to 1632 files (272
active log files along with 5 rollover log files for each). The maximum combined size
of these log files may be up to about 16 GB (1632 files at 10 MB each).
Dialogic
Managing the CX Video Gateway
97
Need help?
Do you have a question about the Vision CX Video and is the answer not in the manual?