3.1.12 THERMOSTAT

The thermostat must be installed on an inside wall in a location where it is not
likely to be affected by the draft coming from an air outlet. It must be installed at
a minimum of 55 inches above the floor. The two thermostats on a combined
system must be installed at the same height. The Mini-Caddy wood Add-on
furnace's thermostat must be positioned between 18°C et 21°C (65°F et 70°F) or
to a temperature slightly higher (2°C à 3°C) than the existing furnace. It controls
the opening or closing of the air intake of the wood Add-on furnace.

3.1.13 SAFETY PRECAUTION

THE OPERATION OF A GAS FURNACE MUST BE VERIFIED FOR
ACCEPTABLE OPERATION BEFORE AND AFTER INSTALLATION OF THE
MINI-CADDY
ADD-ON
RECOGNIZED BY THE REGULATORY AUTHORITY.
DO NOT CONNECT TO ANY GAS FURNACE THAT HAS NOT BEEN
CERTIFIED INITIALLY AS COMPLYING WITH CGA STANDARD CAN/CGA-
2.3 OR ITS PRECEDENTS.

3.1.14 OPERATING INSTRUCTIONS

Operate the existing furnace periodically to ensure that it will operate
satisfactorily when needed.
On the wood furnaces, the thermostat controls the air inlet damper. When the
thermostat calls for heat, the damper opens and the combustion is stirred up.
When the furnace gets hot enough, the fan limit control activates the blower
motor at the speed selected for wood heating.