Power Error Messages; Scsi Error Codes; Scsi Error Codes And Actions - IBM TotalStorage NAS 300 User Reference

Hide thumbs Also See for TotalStorage NAS 300:
Table of Contents

Advertisement

Power error messages

Table 28. Power error messages
Message
Power supply x current share fault
(level-critical; excessive current demand on
power supply x)
Power supply x DC good fault
(level-critical; power good signal not detected
for power supply x)
Power supply x temperature fault
Power supply x removed
Power supply x fan fault (level-critical; fan
fault in power supply x)
Power supply x 12 V fault (level-critical;
overcurrent condition detected)
Power supply x 3.3 V fault (level-critical;
3.3 V power supply x had an error)
Power supply x 5 V fault (level-critical; 5 V
power supply x had an error)
System running non-redundant power
(level-noncritical; system does not have
redundant power)
System under recommended voltage for x
(level-warning; indicated voltage supply
under nominal value; value for x can be +12,
-12, or +5)

SCSI error codes

Table 29 describes SCSI error codes and their suggested actions.
Table 29. SCSI error codes and actions
Error code
Meaning
All SCSI Errors
You might be experiencing one or
more of the following problems:
v A failing SCSI device (adapter,
drive, or controller)
v An incorrect SCSI configuration
or SCSI termination jumper
setting
v Duplicate SCSI IDs in the same
SCSI chain
v A missing or incorrectly installed
SCSI terminator
v A defective SCSI terminator
v An incorrectly installed cable
v A defective cable
148
NAS Gateway 300 User's Reference
Action
Replace power supply x.
Replace power supply x.
Replace power supply x.
No action required - information only.
Replace power supply x.
See "Power checkout" on page 105.
See "Power checkout" on page 105.
See "Power checkout" on page 105.
Replace power supply.
Note: System can continue to operate without redundancy protection.
1. Check connections to the power subsystem.
2. Power supply.
3. Power cage assembly.
Part/action
1. Ensure that the external SCSI devices were
powered-on before the appliance was powered-on.
2. Ensure that the cables for all external SCSI devices
are connected correctly.
3. If you have attached an external SCSI device to the
appliance, make sure the external SCSI termination
is set to automatic.
4. Ensure that the last device in each SCSI chain is
terminated correctly.
5. Ensure that the SCSI devices are configured
correctly.