Table 23. Diagnostic error codes (continued)
Error code/symptom
201-XXX-0NN
201-XXX-999
202-XXX-001
202-XXX-002
206-XXX-000
215-XXX-000
217-198-XXX
217-XXX-000
217-XXX-001
217-XXX-002
217-XXX-003
217-XXX-004
134
NAS Gateway 300 User's Reference
Meaning
Failed memory test.
Multiple DIMM failure, see error
text.
Failed system cache test.
Failed system cache test.
Failed diskette drive test.
Failed IDE CD-ROM drive test. 1. CD-ROM drive cables
Could not establish drive
parameters.
Failed BIOS hard disk test.
Note: If RAID is configured,
the hard disk number refers to
the RAID logical array.
Failed BIOS hard disk test.
Note: If RAID is configured,
the hard disk number refers to
the RAID logical array.
Failed BIOS hard disk test.
Note: If RAID is configured,
the hard disk number refers to
the RAID logical array.
Failed BIOS hard disk test.
Note: If RAID is configured,
the hard disk number refers to
the RAID logical array.
Failed BIOS hard disk test.
Note: If RAID is configured,
the hard disk number refers to
the RAID logical array.
Part/action
1. DIMM Location slots 1-6 where nn = DIMM
location.
Note: nn :
1=DIMM 1
2=DIMM 2
3=DIMM 3
4=DIMM 4
5=DIMM 5
6=DIMM 6.
2. System board
1. See error text for failing DIMMs.
2. System board.
1. VRM 1
2. Microprocessor 1
1. VRM 2
2. Microprocessor 2
1. Cable
2. Diskette drive
3. System board
2. CD-ROM drive
3. System board
1. Check cable and termination.
2. SCSI backplane.
3. Hard disk.
Logical drive 1
Logical drive 2
Logical drive 3
Logical drive 4
Logical drive 5