Table 25. POST error codes (continued)
Error code/symptom
201
229
262
289
301
303
602
604
605
662
762
962
11XX
142
NAS Gateway 300 User's Reference
Meaning
Memory test error. If the
engine does not have the
latest level of BIOS installed,
update the BIOS to the latest
level and run the diagnostic
program again.
Cache error.
DRAM parity configuration
error.
DIMM disabled by POST or
user.
Keyboard or keyboard
controller error.
Keyboard controller error.
Invalid diskette boot record.
Diskette drive error.
Unlock failure.
Diskette drive configuration
error.
Coprocessor configuration
error.
Parallel port error.
System board serial port 1 or
2 error.
Part/action
1. DIMM
2. System board
1. Microprocessor
2. Optional microprocessor (if installed)
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
1. Run the Configuration/Setup Utility program, if
the DIMM was disabled by the user.
2. Disabled DIMM, if not disabled by user.
1. Keyboard
2. System board
System board
1. Diskette
2. Diskette drive
3. Cable
4. System board
1. Run the Configuration/Setup Utility program and
Base System Diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Diskette drive
2. Drive cable
3. System board
1. Run the Configuration/Setup Utility program and
Base System Diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
1. Run the Configuration/Setup Utility program.
2. Battery.
3. Microprocessor.
No corrective action. No parallel device is required
for normal functioning.
1. Disconnect the external cable on the serial port.
2. Run the Configuration/Setup Utility program.
3. System board.

Advertisement