Datalogic AccuLazr AL5010 Product Line Manual page 182

Hide thumbs Also See for AccuLazr AL5010:
Table of Contents

Advertisement

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Modify Settings > Tracking
Tachometer (Encoder) Selections (drop-down list)
Selection
Definition
Hardware/
Used for external hardware tachometer. When this tachometer
mode is used, you must also set the number of pulses per inch
External
(PPI) generated by the tachometer.
(Only available with
T
the Enhanced
a
Interface Module)
c
Constant/Internal
Specify the tach rate to be used (from 25 - 600 ft/min). No
h
external hardware is used.
o
Computed Tach
There are two options available: Start-End and Start-Start. In
m
both cases, you specify the Length (from 1-200 inches)
e
between either a start and end trigger (Start-End) or between
t
one start trigger and the next (Start-Start). From this
information the reader will compute the belt speed and generate
an internal tach signal.