Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
NETWORK LED during Normal Operations
Mode
Description
Single TCP/IP
Solid
NOTE: If both Host 1 and Host 2 are used, the LED will be
solid
Off – No host connection.
NOTE: If UDP messaging is used (unconnected messages)
the Network LED will be off.
EtherNet/IP
Solid
Flashing
Flashing
Controller/Client
Controller
Solid
same group number have been found.
Flashing
number have NOT been found
Client
Solid
group number.
Off – Not connected to a controller with the same group
number.
NOTE: The mode indicated by the Network LED is dependent on the AL5010
configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode
operation is the lowest.
Using Control Panel Buttons to Check Normal Operations
Ref
Button
Restore to Scan
Head
Backup to
Mounting Base
Test /Diagnostic
(Laser Shutoff)
REMEMBER: AL5010's control panel buttons can be enabled / disabled
through the use of the browser-based setup application.
(See Modify > AL5010 Configuration, Enable AL5010 Control Panel
Buttons.)
GREEN
– AL5010 connected to a host.
GREEN
if either port is connected.
GREEN
– AL5010 made a connection to the PLC
GREEN
– No connection made with the network
RED
– Lost network connection
GREEN
– The correct number of client(s) with the
RED
– All the client(s) with the same group
GREEN
– Connected to a controller with the same
Description
Restores parameters from Mounting base to Scan
Head
Button must be pressed twice to initiate action.
See page 99 for procedure.
Downloads parameters from Scan Head to Mounting
base
Button must be pressed twice to initiate action.
See page 99 for procedure.
Enables the AL5010 test mode.
(Test mode can also be selected remotely using
Tools > Commands > Test Mode.)
Use to perform laser shutoff. (See page 107.)