AL5010:C Configuration Data
This data is not used.
AL5010:I Input Data
Tag Name
AL5010:I.Data[0]
Discrete Input Word
AL5010:I.Data[1]
Bar Code Sequence Number
AL5010:I.Data[2]
Bar Code Status
AL5010:I.Data[3]
Bar Code Size (words)
AL5010:I.Data[4-67]
Bar Code Data
Bit
0
AL5010 Programmable Output #1
1
AL5010 Programmable Output #2
2
AL5010 Programmable Output #3
3
AL5010 Programmable Output #4
4
AL5010 Programmable Output #5
5
AL5010 Programmable Output #6
6
AL5010 Programmable Output #7
7
AL5010 Programmable Output #8
8-15
Unused
AL5010:O Output Data
Tag Name
AL5010:O.Data[0]
Discrete Output Word
AL5010:O.Data[1]
Last Bar code Sequence
Number Received
Discrete Output Word
Bit
Bit = 0
0*
Trigger Off
1 – 7
Unused
8*
AL5010 Relay #1 Off
9*
AL5010 Relay #2 Off
10*
AL5010 Relay #3 Off
11*
AL5010 Relay #4 Off
12-15
Unused
* If enabled on AL5010
Value
See bit definitions.
This field is updated every time the bar code
data is updated. However, the bar code data
will only be updated when the "Last Bar Code
Sequence Number" (see Output Data) is set
equal to this value.
Not currently used.
Number of words which contain the bar code
data
Discrete Input Word
Value
See bit definitions.
This field must be updated to match the Bar Code
Sequence Number each time the bar code data
has been processed.
Bit = 1
Trigger On
Unused
AL5010 Relay #1 On
AL5010 Relay #2 On
AL5010 Relay #3 On
AL5010 Relay #4 On
Unused
Description
Description

Advertisement