Datalogic AccuLazr AL5010 Product Line Manual page 51

Hide thumbs Also See for AccuLazr AL5010:
Table of Contents

Advertisement

Electrical wiring sequence:
1.
SCANNER - Mounting base
(two connections, 15-pin 'D' and RJ-45)
ETHERNET - Host (Network)
2.
COM 1 / COM 2 - Serial communications
3.
4.
TRIG – Trigger
5.
POWER - Power supply or user-supplied
Wiring Installation Sequence (Connection Panel)
Wiring Installation Sequence (Circuit Board) and TB Wiring Tables
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Cable Jacket Stripping
COM 1 = 3 1/2", COM 2 = 3"
3 1/2"
2 3/4"
Strip All Wires
1/4"
1/4"
1/4"

Advertisement