• Hardware Trigger
• Software Trigger
• Continuous Trigger
Trigger Source = Hardware Trigger
Selection
Definition
Hardware Trigger
Select Active Low or Active High from the drop-down list.
• Active Low: The trigger is active when the input signal is
low.
• Active High: The trigger is active when the input signal is
high.
Debounce Duration – Defines the minimum time required for
detection of a change in the hardware trigger status.
Trigger Source = Software Trigger
Selection
Definition
Software Trigger
Select a Host n or Net n trigger source from the drop-down list.
The software trigger can be any "host port" either serial or
T
network based.
r
Start Char – Define the ASCII characters that, when received,
i
will start trigger for the reader.
g
g
End Char – Define the ASCII characters that, when received,
will end trigger for the reader.