Output Module Application
Shown below is a typical output module application. When connecting high
impedance loads, you may need to add a resistor in parallel with the load.
This resistor (typically 300 to 6,000 ohms) provides a continuous minimum
current flow (10 mA DC or 50 mA AC) through the output module in the
closed state.
Recommended
-
Output Module TB
+
Optional Resistor for High Impedance Loads
Back Electromotive Force (EMF) is sometimes generated when an
inductive load is switched off. Back EMF may damage the output module. A
diode in parallel with the inductive device dissipates the back EMF.
Recommended
-
Output Module TB
+
Optional Diode to Dissipate Back EMF
An example output module application is the use of a Stack Light. The
AL5010 would use three output modules to send signals to the stack light to
visually indicate specific conditions (e.g., green = read, yellow = multiple
codes, red = no read). (See drawing in Appendix F.)
Input Module Application
Input module 1000056135 is most often used for an End Trigger Photoeye
application. (See drawing 113490 sheet 3 in Appendix F.)
NOTE: Any other input module application requires custom software.
Contact Accu-Sort Customer Service for more information.