Control Panel LED Fault Detect Descriptions
LED
Description
STATUS
RED
indicates a problem regarding the overall "health" of the
reader.
Indicates the trigger input.
TRIGGER
The LED is controlled through software no matter the trigger
source (including software trigger).
READ
RED
identifies a No Read condition.
Check bar code print quality, trigger configuration, and bar code
parameters.
If bar codes are being read, but the LED is NOT illuminated, data
RX/TX
is not being transmitted on serial port 1.
NETWORK
(See Network LED – Fault Detection.)
LINK
If the LED is not flashing, there is no network connection.
Read quality indicator (5 = Good, 1 = Poor).
Bar Graph
5 = 81-100%
(LED 1 – 5)
4 = 61-80%
3 = 41-60%
2 = 21-40%
1 = 00-20%
NOTES: Also flashes during parameter upload/backup.
LEDs stay on when Test/Diagnostic button C is pressed during
(Laser Shutoff)
the laser shutoff procedure.

Advertisement