Datamax E-Class Mark III Professional Operator's Manual page 46

Hide thumbs Also See for E-Class Mark III Professional:
Table of Contents

Advertisement

DISPLAYED ITEM
RIBBON LOW OPTIONS
RIBBON LOW
DIAMETER
0.50
PAUSE ON RIBBON
LOW
ENABLE
DISABLE
SENSOR CALIBRATION
QUICK CALIBRATION
MANUAL CALIBRATION
ADVANCED ENTRY
PAPER SENSOR
LEVEL
REFL PAPER LEVEL
GAP SENSOR LEVEL
MARK SENSOR
LEVEL
EMPTY SENSOR
LEVEL
TRAN SENSOR
GAIN
REFL SENSOR GAIN
PRINTHEAD CLEANING
CLEAN HEAD SCHEDULE
CLEAN HEAD COUNTER
RESET COUNTER
CLEAN HEAD NOW
40
Defines the printer response when THERMAL TRANSFER mode is selected and the ribbon supply
begins to diminish.
Sets the ribbon supply threshold diameter (1.00 - 2.00 inches) that will trigger a Low Ribbon
Warning prompt, where:
Is the default setting.
Allows the printer to enter a paused condition when Ribbon Low Diameter is met, where:
Pauses when a Ribbon Low Diameter condition is detected; the PAUSE Key must be pressed to
proceed with the print job.
No action is required by the operator; printing can continue until a Ribbon Fault is declared.
(Default Setting)
Selects the media sensor calibration method, where:
Sets the values via internal printer calculations by feeding blank labels through the printer.
Manual calibration that scans media and backing and out of stock condition to calculate the proper
calibration.
Sets the values via manual entry (typically for hard to calibrate label stocks), as described in the
ADVANCED ENTRY CALIBRATION where:
Establishes the threshold for the paper value (0 - 255), where 170 is the default setting.
Establishes the threshold for the reflective value (0 - 255), where 170 is the default setting.
Establishes the threshold for the gap value (0 - 255), where 040 is the default setting.
Establishes the threshold for the mark value (0 - 255), where 040 is the default setting.
Establishes the threshold for the empty value (0 - 255), where 000 is the default setting.
Establishes the sensitivity of the transmissive sensor (0 - 31), where 15 is the default setting.
Establishes the sensitivity of the reflective sensor (0 - 31), where 15 is the default setting.
Controls the automatic cleaning alert and function, where:
Specifies the inch (or centimeter) count at which to clean the printhead, and if exceeded three
times, declare a Head Cleaning Fault. (Note that the specified count [0 - 200 inches] will be
multiplied by one thousand, and that zero [the default setting] will disable the function.)
Indicates the number of inches (or centimeters) since a cleaning was last initiated.
Resets the Clean Head Counter to zero to restart the Clean Head Schedule.
Initiates the cleaning process and resets the Clean Head Counter.