Advanced Entry Calibration (continued)
Step
Action
Using the
or
Gain Number determined in the
L
previous step. Press the
to enable the setting.
Press the
button again to re-
enter the TRAN SENSOR GAIN (or
REFL SENSOR GAIN, if using
reflective media) menu item.
Complete a table (see example
below) using new measurements,
as follows:
(A) Raise the Cover Assembly.
Place the label over the Media
Sensor then lower and latch the
Cover Assembly. Record the
sensor reading as "Paper".
M
(B) Raise the Cover Assembly.
Place the liner, notch, or mark
over the Media Sensor then lower
and latch the Cover Assembly.
Record the sensor reading as "Gap
(or Mark)".
(C) Raise the Cover Assembly.
Remove all media from the Media
Sensor then lower and latch the
Cover Assembly. Record the
sensor reading as "Empty".
Gain Number
Chapter 3 – Printer Operation
Displayed Message
button, set the
button
TRAN SENSOR GAIN
Paper
18
174
OK
18
yyy
(0 - 31)
Selected Gain Table
Gap (or Mark)
42
Comment
This example uses Gain Number
18.
Where "yyy" is a numerical value
representing the current sensor
reading.
The re-sampled values may
differ from those previously
noted. This is normal; do not
readjust the Media Sensor.
Empty
9
35