2HA/2HB
Maintenance
item No.
Stabilizing fuser forcibly
U162
Description
Stops the stabilization fuser drive forcibly, regardless of fuser temperature.
Purpose
To forcibly stabilize the machine before the fuser section reaches stabilization temperature.
Method
1. Press the start key. "on" appears.
2. Press the start key. The forced stabilization mode is entered, and stabilization operation stops regard-
less of fuser temperature. The indication for selecting a maintenance item No. appears. To exit the
forced stabilization mode, turn the power off and on.
Completion
Press the stop/clear key. The indication for selecting a maintenance item No. appears.
Resetting the fuser problem data
U163
Description
Resets the detection of a service call code indicating a problem in the fuser section.
Purpose
To prevent accidents due to an abnormally high fuser temperature.
Method
1. Press the start key. "CLE" appears.
2. Press the start key. The fuser problem data is initialized.
Completion
Press the stop/clear key. The indication for selecting a maintenance item No. appears.
Checking the fuser count
U167
Description
Displays the fuser count.
Purpose
To check the fuser count.
Method
1. Press the start key.
2. Select the item using the exposure adjustment keys.
Exposure indicator
Exp. 1
Exp. 2
Completion
Press the stop/clear key. The indication for selecting a maintenance item No. appears.
1-3-36
Description
Copy quantity display
First 3 digits of the fuser count
Last 3 digits of the fuser count

Hide quick links: