1. The size of the  replace cavity required to insert the 530 engine varies with the
style of front trim chosen. Refer to the front trim installation manual for required
dimensions.
2. Place the appliance ( tted with the co-linear adapter) near the  replace opening but
allow space for manipulating the chimney liners on to the appliance.
3. Drop the 3-inch diameter  exible liners into the chimney from outside.
4. Fit the liners to the co-linear adapter paying attention to inlet and exhaust and move
the appliance to its proper position. Be aware of the minimum liner bend radius and
maximum liner horizontal run as shown on page 24 in this manual.
5. Fit the termination kit and  ashing if required to the exterior of the chimney.
6. Secure the appliance to the  oor or wall if necessary.
Window Removal
1. Release the top of the window by pulling forward and rotating
outwards the two bars at the top corners.
2. Unscrew the two spring-loaded bolts securing the bottom of the
window.
3. Carefully lift the window. Keep the window and bolts in a safe
place.
4. Remove the packaged ceramic (Bricks/Logs/Coals/Rocks) from
 rebox.
Burner Module Removal
It may be desirable to remove the burner module to gain access
for gas  tting, to install a fan kit, or to fasten the unit to the  oor or
plinth supplied with the zero clearance fronts.