Vent Outlet Preparation for Co-axial Installations using Non-Valor Vent
Components
If installing straight off the back venting with Valor terminal kit 551DVK only, ignore this
step:
1. Fit the adapter 817VAK over the appliance vent collars pushing on  rmly.
Align the adapter so that the seam on horizontal pipes is not at the bottom
——check by temporarily  tting a pipe.
2. Drill through the adapter outer tube and appliance outer collar for #6 screws.
Make sure that the drill does not penetrate the inner tubes.
3. Secure the adapter to the outer collar with two #6 thread cutting screws supplied.
Co-linear Conversion using Listed Generic Adapter Box
1. Fit the adapter 817VAK over the appliance vent collars pushing on  rmly.
2. Fit and fully twist-lock the co-axial-to-co-linear adapter to the 817VAK
adapter.
3. Keeping the connector and adapter fully twist-locked, rotate them so
that the air inlet collar on the connector is at the bottom.
4. Drill through the adapter outer tube and appliance outer collar for no.
6 screws. Make sure the drill does not penetrate the inner tubes.
5. Secure the adapter to the outer collar with two no. 6 thread cutting
screws supplied.
Co-linear Conversion using Valor 556CLA Co-linear Adapter
(Note: Instructions may vary as 556CLA may be installed on Top or Back of Heater.)
1. Remove the blank plate and gasket to gain access to the exhaust spigot. Retain the plate and gasket
for re-use later.
2. Remove the existing outer intake plate. Retain the gasket only for re-use.
3. Remove the existing exhaust spigot——the gasket below should remain on the heater.
4. Install the new co-linear exhaust spigot re-using existing screws. Ensure all screws are reinstalled tightly.
5. Install the new co-linear outer plate (note: up/down front/back orientation on drawing) re-using existing
gasket and screws. Use 6 additional screws supplied to seal outer plate to gasketed  ange of exhaust spigot.
Connect the 3-inch diameter  ex liners directly to
outer plate collars using sheet metal screws.
Note: "exhaust" & "intake" must correspond
with roof termination.
Re-use gaskets
if in good
condition.
If not, clean
and use
supplied gaskets.
Remove existing outlet
28
Appliance Preparation
This is the bottom edge when installing as rear outlet
This is the front edge when installing as top outlet
Replace existing outlet with 556CLA kit
3" Exhaust
3" Inlet
Gaskets
817VAK
Exhaust
collar