Approvals and Codes
This appliance is certi ed to ANSI Z21.88a––2012/
CSA 2.33a––2012 American National Standard/CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA.
The appliance complies with CSA P4.1-09, Testing
method for measuring annual fi replace effi ciencies.
The installation must conform with local codes or, in
the absence of local codes with the National Fuel Gas
Code, ANSI Z223.1or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only quali ed
licensed or trained personnel should install the
appliance.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1.
Ratings
Altitude (Ft)
Input Max. (Btu/h)
Input Min (Btu/h)
Manifold pressure (in.w.c.)
Min. Supply pressure (in. w.c.)
Max. Supply pressure (in. w.c.)
*Tested to CGA - 2.17-91 Gas fi red appliances for use
at high altitudes. In USA, installations may require
deration over 2000’' ——Check local codes.
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation——consult your local gas utility
to con rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Speci cations
NG
LPG
0-4500 *
20,500
19,000
6,500
12,500
3.5––3.9 10.3––10.7
5
11
10.5
14
Supply Gas
Heater engine 530ILN/ICN/IRN is used for natural gas
installations.
Heater engine 530ILP/ICP/IRP is used for propane gas
installations.
The supply pressure must be between the limits shown
in the Ratings table on the previous page.
The supply connection is 3/8 inch NPT female located
at the left side of the control valve.
The opening for the gas supply line is at the rear left
corner of the appliance.
Gas line ac-
cess at rear
left corner
Gas supply connection
3/8”" NPT female at valve
Controls
The unit is supplied standard with a battery operated,
hand-held remote control and receiver which has the
ability to light the pilot and adjust the gas input of the
unit between the pilot setting and the maximum input.
The pilot light may be left on or turned off with each
use to save energy. The remote control provides full
thermostatic or manual operation with the option of
programming thermostat function between certain
times of the day. Manual operation of the valve is also
possible should the batteries or remote control fail.
Electrical
The unit does not require an electrical power source
unless  tted with an optional circulating fan.
Fuel Beds
The 530I engine is available in either natural gas or
propane gas and comes equipped with either a simu-
lated logs, coals, or rocks fuel bed in either fuel.
QUALIFIED