Variance in voltage affects treadmill performance
1. Confirm incoming line voltage: 120/220VAC –
PWM Units:
SCR Units:
For 115V and 230V rated PWM's acceptable variance is + or - 8%. For SCR's acceptable variance
is + or - 10%.
2. Confirm 12-17 VDC (plug into outlet) output voltage from DC (Transformer) pack.
3. Confirm 10 VDC (for 110V) and 20 VDC (for 220V) out of Motor Control Board per mile per
hour. See example
Example:
SCR: Measure between MTR+ and MTR-
PWM: Measure between A+ and A-
In both of these examples we have should have a voltage reading of 30VDC for 110V and 60VDC
for 220V @3mph.
4. Confirm 12-17 VDC between Black and Green wires on main wire harness. This is power being
delivered to the upper display board.
5. Confirm incoming voltage: 6-7 VDC between V+ and P1, 0-7VDC between P1and P2 (will vary
in relation to speed indicated)
VOLTAGE TESTS
Measuring between Hot and Neutral on relay board.
Measuring between L1 and L2 wires on PWM board.
Measuring between Hot and Neutral on SCR board.