SOUND ONLY COMES FROM ONE OF THE TWO SPEAKERS

Check speaker harness connections on the back of the display board. Swap the left and right
connections. If the same speaker doesn't play, the speaker is bad. If the other speaker doesn't
play, the display board is bad.
MUSIC DOESN'T SEEM TO PLAY AT ALL.
-The display will show "CDERR" if it cannot communicate with the changer. If you see that error,
try to eject the CD cartridge. If it does not eject, check and reset the changer harness connections.
If the harness looks good, the most likely part to replace is the changer itself. If that doesn't work,
replace the display board.
-Turn the volume knob clockwise, volumes below 8-12 may be inaudible depending on ambient
noise.
-Turn the CD/TRACK knob to see if its possible to change tracks. If you can change tracks but no
music plays, the display board audio amp may be blown so replace the display board.
-If the display shows "–LOAD" after you turn the CD/TRACK knob, it is still looking for a CD. It
searches the cartridge in order from slot 1 to slot 6, so if you only have a CD in slot 6, it will take a
while to get there before it begins to play.
-Try another CD, this one may be scratched.
-Some, but not all CD copies (CDR, CDRW) will play in the changer. If a copied CD is not playing,
try an original CD.
HOW TO REMOVE CD CHANGER: To gain access to relay board and pwm motor control.
1. Unplug treadmill from wall.
2. Remove motor cover.
3. Unplug AC power cord going to DC power pack.
4. Remove (3) Philips head screws securing CD mounting rack to motor pan.
5. Carefully lift CD changer and mount, as an assembly, and rotate out of the way.
NOTE: Be very careful not to damage the wires running though the access port on the
CD mount.
NOTE: When installing, make sure not to crimp any of these wires between the CD
mount and motor pan.

HOW TO REMOVE MEMBRANE PANEL ASSEMBLY:

1. Unplug treadmill from wall.
2. Remove speed and elevation control knobs (grip and turn in a ccw direction).
3. Remove control panel end caps.
4. Remove membrane panel assembly by lightly pulling towards you to release Velcro.
NOTE: Be very careful not to damage any wires.
NOTE: When installing the speed and elevation knobs, elevation is black and speed is
red.