ELECTRICAL REQUIREMENTS FOR L-SERIES TREADMILLS

FOR 220V & 110V MACHINES USING 3 PHASE VOLTAGE: Each treadmill must have its own circuit
breaker and be run on the same phase same power leg). If 220v power is required then all
treadmills must run on the same two phases (power legs) and on their own circuit breakers.

220 VAC CLUB TREADMILL

220V CLUB ELECTRICAL REQUIREMENTS:
220VAC , 60 Hz , 15 AMP - DEDICATED CIRCUIT & GROUND
PLUG - NEMA 6-15P (PLUG)
RECEPTACLE - NEMA 6-15R (RECEPTACLE)
ABOVE IS DIAGRAM OF PLUG CONFIGURATION.
110 VAC HOME, LTD, & CLUB TREADMILL
HOME, LTD, & 110V CLUB ELECTRICAL REQUIREMENTS:
110 VAC , 60 Hz , 15 AMP - DEDICATED CIRCUIT & GROUND
PLUG - NEMA 5-15P (PLUG)
RECEPTACLE - NEMA 5-15R (RECEPTACLE)
ABOVE IS DIAGRAM OF PLUG CONFIGURATION