L-Series Executive Trainer Error Codes:; Safety Shutdown / Loss Of Signal - Landice L Series Diagnostic And Service Manual

L series home and commercial treadmill
Hide thumbs Also See for L Series:
Table of Contents

Advertisement

L-SERIES EXECUTIVE TRAINER ERROR CODES:

The Executive Trainer software is designed with special error codes to display when experiencing
a system failure. Here is a list of error codes, their meanings and diagnostics.
Error Code: SAFETY SHUTDOWN / Loss of signal
Meaning: upper display is not receiving signal from speed sensor.
Diagnostics: Refer to diagnostic guide: LS error, treadbelt movement.
Error Code: SAFETY SHUTDOWN / Loss of signal
Meaning: upper display is not receiving signal from speed sensor because the drive motor is not
moving.
Diagnostics: refer to diagnostic guide: LS error, treadbelt does NOT move.
Error Code: SAFETY SHUTDOWN / Error detected in elevation controller
Meaning: Elevation potentiometer is out of calibration and/or system failure.
Diagnostic: Refer to diagnostic guide: Elevation system failure, "PO"
NOTE:
Regular start up: pressing the OK button will over ride the error and allow the treadmill to
run.
(WITH belt
movement)
(NO belt
movement)
LS will appear in the two-digit
displayed speed window
PO will appear in two-digit
speed window.