Message
Description
Press END to quit
The handset is waiting to acquire
bandwidth required for voice
communication.
Prom Bad Length
The handset software downloaded files
that are incorrect or corrupted.
Registering
The handset has completed
initialization of the SIP application and
is attempting to register lines to the
SIP proxy servers.
RTP Open Failed
The handset attempted to open an
RTP port for audio but was
unsuccessful.
Select License
The correct protocol has not been
selected from the license set.
Server Busy
Handset is attempting to download
from a TFTP server that is busy
downloading other devices and
refusing additional downloads.
SIP Login
Prompt for login information –
username and password.
Skt Open Fail
Socket open fail. Occurs when the
handset attempts to open a connection
to the proxy server but fails.
The SpectraLink 8000 SVP Server has
Service Rej.
rejected a request from the handset.
Storing Config
Handset is storing changes to handset
configuration.
The SpectraLink 8000 SVP Server has
SVP Service Rej.
rejected a request from the handset.
PN: 1725-36038-001-H.doc
Action
Press END or wait until bandwidth is
available.
Download new software from the OEM
Software Maintenance
site per
If registrations are failing, the phone can
stay in this state for a considerable
length of time. After the phone leaves
this state, press the LINE key to view
what lines have failed to register.
Ensure usernames and passwords
have been entered in administrative
menus for registrations that have failed
and that proxy information is correct in
the SIP configuration files.
Verify that SpectraLink 8000 SVP
Server capacity has not been
exceeded.
Using the Admin menu, select one
license from the set to allow the phone
to download the appropriate software.
None, the handset will automatically
retry the download every few seconds.
At power-on initialization, no username
was detected in the Admin menu items
for SIP registrations. Enter a valid
username and password for an existing
SIP configuration file.
Verify that SpectraLink 8000 SVP
Server capacity has not been
exceeded.
The handset will restart and attempt to
re-register with the SpectraLink 8000
SVP Server, which should fix the
problem. Report to your administrator if
it keeps happening.
None. Informational only. The handset
may display this briefly following a
configuration change or software
download.
The handset will restart and attempt to
re-register with the SVP Server, which
should fix the problem. Report to your
administrator if it keeps happening.
Troubleshooting
.
133
Need help?
Do you have a question about the SpectraLink 8020 and is the answer not in the manual?
Questions and answers