1.9
Wiring for Single Unit – Intercom Mode
Phone
Jack
Vehicular Gate
Operator
Mag Lock
Power
3
Pedestrian
Gate / Door
A
When connected directly to a single telephone or an un-
used C.O. port on a PBX or KSU system, use the PHONE
OUT terminals only. The 1812 must be programmed for
INTERCOM mode using this configuration.
When the 1812 is programmed for intercom mode, it
provides the constant source of DC voltage necessary for
communication. The intercom mode also disconnects the
phone in terminals (1 and 2) since they are not used.
Be sure that the 1812 is programmed in the intercom mode
when connecting the unit as shown above.
This device is powered by a 16.5 VAC
transformer. DO NOT power this device with a
24 VAC transformer or power source.
Page 18
1
A
2
3
4
1
5
6
7
5
8
9
10
11
12
4
13
14
15
16
16.5 VAC
17
20 VA
4
18
2
Use only twisted pair telephone wire that is rated for direct underground burial. DO NOT
use wire that is intended for indoor applications . Recommend Cat5e Gel Filled
1
(flooded) UV Resistant Direct Burial Cable. DO NOT run telephone wires and high
voltage wires in the same conduit. Check the phone wire chart for wire size / distance.
Use supplied 16.5 VAC, 20 VA power transformer or UL Listed equivalent. DO NOT
2
Power this device with a 24 Volt transformer or source voltage.
Magnetic locks or electric strikes must be powered from a separate UL Listed power
3
transformer. Do not power strikes or magnetic locks from the 1812 power transformer.
Use minimum 18 AWG wire for runs up to 100 feet; 16 AWG wire for runs up to 200 feet. It
is recommended to keep power wire runs as short as possible. Check the power wire chart
4
for wire size / distance.
Be sure to properly ground all devices. Minimum 12 AWG wire.
5
1
2
RS-485 RX
3
BAD DNS
LAN DOWN
4
ON
SW1
MODEM / TCP ENB
5
Phone Line
6
In Use
7
8
Keypad
1 2 3 4 5 6 7 8 9 1011
DOORKING, INC., INGLEWOOD, CA 90301
Title:
1812 Access Plus – single system.
Basic wire connections intercom mode.
Date:
2/09
Dwg. No.
M1812AP-003
1812-162-B-6-09
Master
Code
Mic
Vol
Speaker
Vol
A
Rev.