Wiring Diagram - Single Unit - Telephone Mode - DKS 1812 Owner's Manual

Pc programmable residential telephone intercom / access control system
Hide thumbs Also See for 1812:
Table of Contents

Advertisement

1.7
Wiring for a Single Unit – Telephone Mode
White/Blue
White/Blue
From Phone
Company
Blue/White
Blue/White
White/Orange
Orange/White
By-Pass
A
Switch
Vehicular Gate
Operator
Mag Lock
Power
5
Pedestrian
Gate / Door
A
Locate the telephone company demarcation device.
IMPORTANT! Identify the wires that connect to the
homeowner's telephones. Disconnect these wires from
the demarcation device and connect them to terminals 7
and 8 on the by-pass switch.
Connect a twisted-pair telephone wire to terminals 1 and 2
on the by-pass switch. Connect the other end of these
wires to the telephone company demarcation device where
you removed the wires from above.
Place the by-pass switch in the "BY-PASS" position until
the 1812 unit is installed. Test the homeowner's telephone.
They should have dial tone while the switch is in the BY-
PASS position.
B
Optional DoorKing Surge Suppresser P/N 1877-010 (or
equivalent) highly recommended.
For best protection, surge suppresser ground wire must be
3-ft. or less in length. Use minimum 12 AWG wire.
Ring is Positive with respect to Tip terminal. See
C
Maintain polarity!
PH IN #3 connects to Term 1.
PH IN #4 connects to Term 2.
PH OUT #5 connects to Term 5.
PH OUT #6 connects to Term 4.
This device is powered by a 16.5 VAC
transformer. DO NOT power this device with a
24 VAC transformer or power source.
Page 16
B
GND
7
7
1
3
2
3
4
5
6
7
7
8
9
10
11
12
6
13
14
15
16
16.5 VAC
17
20 VA
6
18
4
Mount the by-pass switch in a location that is easily accessible by the homeowner. The By-
Pass switch IS NOT optional – it must be installed as part of the 1812 system. If
1
installed outdoors, be sure to protect the by-pass switch from direct exposure to rain, snow
and other elements.
Use only twisted pair telephone wire that is rated for direct underground burial. DO NOT use
wire that is intended for indoor applications . Recommend Cat5e Gel Filled (flooded)
2
UV Resistant Direct Burial Cable in conduit. DO NOT run telephone wires and high
voltage wires in the same conduit. Check the phone wire chart for wire size / distance.
Check for polarity on the phone "IN" wires, terminals 1 and 2. Terminal 2 must be positive
with respect to terminal 1. Set a VOM meter to measure DC volts. Place the positive lead on
terminal 2 and the negative lead on terminal 1. If the meter shows a positive voltage - OK. If
3
the meter shows a negative voltage (needle moves off scale to the left), reverse the wires on
terminals 1 and 2.
Use supplied 16.5 VAC, 20 VA power transformer or UL Listed equivalent. DO NOT
4
Power this device with a 24 Volt transformer or source voltage.
Magnetic locks or electric strikes must be powered from a separate UL Listed power
5
transformer. Do not power strikes or magnetic locks from the 1812 power transformer.
3
Use minimum 18 AWG wire for runs up to 100 feet; 16 AWG wire for runs up to 200 feet. It is
recommended to keep power wire runs as short as possible. Check the power wire chart for
6
wire size / distance.
Be sure to properly ground all devices. Minimum 12 AWG wire.
7
ENTRY
BY-PASS
1
DOORKING
1875-010
3
C.O.
PH IN
PH OUT
HOME
1
2
3
4
5
6
7
8
C
2
1
2
3
BAD DNS
4
5
6
7
8
DOORKING, INC., INGLEWOOD, CA 90301
Title:
1812 Access Plus – single system.
Basic wire connections.
Date:
House Phones
Phone
Phone
Phone
Jack
Jack
Jack
Master
Code
RS-485 RX
LAN DOWN
ON
SW1
MODEM / TCP ENB
Phone Line
In Use
Mic
Vol
Keypad
Speaker
Vol
1 2 3 4 5 6 7 8 9 1011
B
6/09
Dwg. No.
M1812AP-001
Rev.
1812-162-B-6-09