Sub-Net Mask; Set The Gateway (Router) Ip Address; Set The Port Number - DKS 1812 Owner's Manual

Pc programmable residential telephone intercom / access control system
Hide thumbs Also See for 1812:
Table of Contents

Advertisement

2.3.3 Sub-Net Mask (reboot required)
Default value is: 255.255.255.000
All sub-net mask should be set to 255.255.255.000. If not, consult your network expert. Valid values
for any of the three digit numbers is 000 to 255.
1. Press * 5 2 and enter the MASTER CODE. [* 5 2 _ _ _ _ (beep)]
2. Enter the sub-net mask number. Use the * key to enter the "dot."
[ _ _ _ * (beep) _ _ _ * (beep) _ _ _ * (beep) _ _ _ * (beep)]
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
2.3.4 Set the Gateway (router) IP Address (reboot required)
Default value is: 192.168.001.001
If the 1812 is connected directly to the computer with a crossover cable, then this address must be
set to 000.000.000.000. If the 1812 is connected to the computer through a router, then set this value
to the router's IP address. Valid value for any of the three digit numbers is 000 to 255.
1. Press * 5 3 and enter the MASTER CODE. [* 5 3 _ _ _ _ (beep)]
2. Enter the gateway (router) IP address. Use the * key to enter the "dot."
[ _ _ _ * (beep) _ _ _ * (beep) _ _ _ * (beep) _ _ _ * (beep)]
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
2.3.5 Set the Port Number (reboot required)
Default value is: 01030
This must be the same port number that was programmed in the software. Valid values are 01024 to
65535.
1. Press * 5 6 and enter the MASTER CODE. [* 5 6 _ _ _ _ (beep)]
2. Enter the port number, then press *. [ _ _ _ _ _ * (beep)]
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
If you are using a computer with the 1812 Access Plus, no other programming at the keypad is
required.
All programming parameters beyond this point can be set in the Management
software.
Page 30
STOP!
1812-162-B-6-09