Wiring Diagram - DKS 1802-EPD Owner's Manual

Telephone entry systems
Table of Contents

Advertisement

2.2

Wiring Diagram

Field Wire Diagram - 1862-010 Control Board
Phone Line Wiring Max Distance
Phone
800 Feet
24 AWG
Line
1600 Feet
22 AWG
5
16 Volt, 20 VA UL Listed power transformer.
1
Power for door strikes or magnetic lock is not provided by the
2
system. It must be provided by an external power supply.
Electric strikes are wired to Normally Open (N.O.) contacts; magnetic
3
locks are wired to the Normally Closed (N.C.) contacts.
4
Optional 12 Volt gel cell for backup power.
5
Dedicated Central Office (C.O.) phone line - touch tone, loop start.
A switch closure across terminals 4 & 8 will activate relay 1 for its programmed
6
strike time. This is where the postal switch is prewired.
A switch closure across these terminals will activate relay 2 for its programmed strike
7
time or cause the system to dial a preprogrammed phone number. See 3.1.6.
8
Display must be removed to access these terminals (1802-EPD models only).
All wiring to be performed in accordance with National Electric Code.
Gate
Operator
Strike /
Mag Lck
3
1
SWITCH 2
INPUT
2
7
8
MAIN TERMINAL
1
2
3
4
5
6
7
6
Earth
Ground
4
Lock
Pwr
2
1862-010
Circuit Board
NO NC COM
RELAY 2 CONTACTS
8
9
10 11 12 13 14
Lock
Strike /
Pwr
Mag Lck
2
3
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Field Wire Diagram - 1862 Control Board
Date:
8/06
1802-065-A-8-06
Power Wiring Max Distance
PWR
100 Feet
18 AWG
INPUT
200 Feet
16 AWG
1
Gate
Operator
B
Dwg. No.
M1800-065-11
Rev.
Page 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

1802

Table of Contents