Input/Output; Default Settings - Dalsa 1M28-SA User Manual

One megapixel cmos stop action camera family
Hide thumbs Also See for 1M28-SA:
Table of Contents

Advertisement

26

2.3 Input/Output

!
WARNING: It is extremely important that you apply the appropriate voltages to your camera.
Incorrect voltages will damage the camera.

2.4 Default Settings

The camera powers-up for the first time with the following default settings.
Table 6: Default Settings
Specifications
EXSYNC
Data output
Output response
Gain
Resolution
Exposure time
Frame rate
Data rate
03-32-00525-04
PRELIMINARY
1M28
1M75
Internal, free-running
Internal, free-running
8-bits
8-bits
Linear
Linear
1x
1x
Full-resolution, 1024 x
Full-resolution, 1024 x
1024
1024
10 ms
12 ms
20 fps
25 fps
28MHz
2x40MHz
1M28, 1M75, and 1M150 User's Manual
+5V and Ground
Diagnostic LED
Camera Link™
1M150
Internal, free-running
8-bits
Linear
1x
Full-resolution, 1024 x
1024
20 ms
20 fps
2x80MHz