Dalsa 1M28-SA User Manual page 16

One megapixel cmos stop action camera family
Hide thumbs Also See for 1M28-SA:
Table of Contents

Advertisement

16
Figure 9: Output Signal (DS-11-01M28) at Different LinLog Values. Integration time: t
I = 535 µW/cm
250
200
150
100
50
0
When using the 4x hardware gain option (HIGH_GAIN = ON), the compression may be
ineffective (the A/D converter is out of range) because the logarithmic compression is only
effective on the upper intensity values. If it is necessary to use a camera with a logarithmic
response curve, the LinLog technology will not replace it completely. On demand, DALSA
cameras can be modified to fulfil these needs.
If necessary, a look-up table (LUT) can be used to improve and adjust the characteristics to the
application. Please ask our support for more information.
Parameter Adjustment Procedure for LL2
There is no direct formula for the interactions of LL1, LL2, and COMP. To determine optimal
settings, use the flowchart on the next page.
03-32-00525-04
PRELIMINARY
2
and wavelength: λ = 850 nm
0
25
50
62.5
75
81.3
LinLog Value
1M28, 1M75, and 1M150 User's Manual
= 1 ms, intensity:
int
Mean
87.5
100
DALSA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1m75-sa1m150-sa

Table of Contents